Article 1. 2. Health and Safety. Title 1. 6, Division 9, California Code of Regulations. Board of Barbering and Cosmetology§ 9. Health and Safety Definitions. The following words and terms, when used in this article, shall have the following meanings: Autoclave A device used to sterilize tools, equipment and supplies by subjecting them to high pressure saturated steam.
Over- the- Counter Cosmetology, barbering or electrology products that are made available for purchase by the general public without a physicians prescription. Cosmetics Substances used to enhance the appearance of the human body. Contaminated The presence of blood or other potentially infectious materials on an items surface or visible debris such as dust, hair and skin. Dermis The layer of skin just below the epidermis; the living layer of the skin.
Article 12. Health and Safety. Title 16, Division 9, California Code of Regulations. Board of Barbering and Cosmetology § 977. Health and Safety Definitions. Potting Machines. Serving the Horticultural Industry for Over 82 Years! H H II G G H H. TUNNELS TUNNELS TUNNEL S. 4500 Earth City Expressway Earth City, Missouri.
Delaney clause; Federal Insecticide, Fungicide, and Rodenticide Act; Good Laboratory Practice; Maintenance fee; Pesticide misuse; Restricted use pesticide. Bifunctional Polymer-Metal Nanocomposite Ion Exchange Materials | InTechOpen, Published on: 2012-11-07. Authors: Berta Domènech, Julio Bastos-Arrieta, Amanda Alonso, et. An effective dose (ED) in pharmacology is the dose or amount of drug that produces a therapeutic response or desired effect in some fraction of the subjects taking it. This table contains information on each unique technology nominated for the Presidential Green Chemistry Challenge from 1996 through 2015. Although EPA has received.
Disinfect or Disinfection The use of chemicals to destroy harmful bacteria, viruses and pathogens on implements or tools to render them safe for use. Disinfectant A product registered by the U. S. Environmental Protection Agency (EPA) that has demonstrated bactericidal, fungicidal and virucidal activity. The products used must include a label from the manufacturer that indicates the EPA registration and must be in liquid form to disinfect non- electrical tools and spray or wipe form to disinfect electrical tools and shears. Dry Heat Sterilizer A device used to sterilize equipment and supplies by use of hot air that is nearly or completely free of water vapor. Epidermis The outermost layer of the skin; the non- living layer of the skin. Electrical Tools All tools used for barbering, cosmetology and electrology that require electricity to operate by means of an electrical cord, wireless charger, or battery.
These include, but are not limited to clippers, blow dryers, curling irons and flat irons. Foot Basin On a footspa chair, the open vessel that is filled with water and in which the clients feet are placed during a pedicure.
Authority: A.R.S. § 32-301 et seq. Editor's Note: 4 A.A.C. 5 consists of new rules for the Board of Barbers that.
- Readbag users suggest that List of License List by Company is worth reading. The file contains 233 page(s) and is free to view, download or print.
- This “GENERIC” Operations and Maintenance Program. An O&M program is not required by Federal or State regulations for commercial office. ASBESTOS LICENSE #.
License Required To Use Bactericide Means
License Required To Use Bactericides
Hot Styling Tools Tools that utilize heat to style hair. Non- Electrical Tools All tools used for barbering, cosmetology and electrology that do not use any form of electricity to operate. These include, but are not limited to shears, razors, cuticle nippers, cuticle pushers, nail clippers, metal files, metal smoothers, combs and hair clips. Poisonous A substance that can cause sickness or death by entering or touching the body. Sanitary A clean, healthy condition. Soiled — dirty; not clean. Sterilize or Sterilization The process which removes or kills all forms of microbial life, including transmissible agents (such as fungi, bacteria, viruses and spore forms) by use of an autoclave or dry heat sterilizer.
Tub A standalone, open vessel that is filled with water and in which the clients feet are placed during a pedicure. Note: Authority cited: Section 7. Business and Professions Code. Reference: Section 7. Business and Professions Code. Minimum Equipment and Supplies(a) Establishments and schools shall have and maintain the following minimum equipment and supplies: (1) If hair services are performed, at least one covered waste container per establishment for the disposal of hair.
Hair must be disposed of in a covered waste container.(2) Closed containers to hold all soiled towels, gowns, smocks, linens and sheets in any enclosed area frequented by the public.(3) Closed, clean cabinets, drawers, or containers to hold all clean non- electrical tools, towels, gowns, smocks, linens and sheets.(4) Containers for disinfectant solution for tools and equipment to be disinfected. Containers must be labeled Disinfectant Solution.(5) Each container specified in (4) shall contain sufficient disinfectant solution to allow for the total immersion of tools.(6) If electrolysis is performed, an autoclave or dry heat sterilizer that meets the requirements of Section 9. Establishments and schools shall have disinfectant solution, mixed according to manufacturer's directions, available for use at all times.(c) A manufacturer- labeled container for the disinfectant used must be available at all times in the establishment or school.
In the event that the last remaining disinfectant has been used, the empty manufacturer- labeled container must be present. Note: Authority cited: Section 7. Business and Professions Code. Reference: Section 7. Business and Professions Code. Disinfecting Non- Electrical Instruments and Equipment(a) Before use upon a client, all non- electrical tools that can be disinfected, excluding shears, shall be disinfected in the following sequential manner: (1) Remove all visible debris.(2) Clean with soap or detergent and water.(3) Completely dry tools with a new, clean paper towel.(4) Then totally immerse in an EPA- registered disinfectant with demonstrated bactericidal, fungicidal, and virucidal activity, used according to manufacturer's instructions.(5) Licensees or students shall wear protective gloves or use tongs when removing tools from the disinfectant.(b) The disinfectant solutions specified in subdivision (a) shall: (1) Remain covered at all times.(2) Be changed according to the manufacturers instructions or when it is cloudy or contains debris. All tools used on a client or soiled in any manner shall be placed in a container labeled Dirty, Soiled, or Contaminated.(d) All disinfected tools shall be stored in a clean, covered place which is labeled Clean or Disinfected.(e) Disinfected tools shall not be placed in a container, pouch or holder which cannot be disinfected.
Shears shall be disinfected according to the following sequential procedures: (1) Remove all visible debris.(2) Clean with soap or detergent and water.(3) Spray or wipe the shear with an EPA- registered disinfectant with demonstrated bactericidal, fungicidal, and virucidal activity, used according to manufacturers instructions.(g) Disinfected shears shall not be placed in a container, pouch or holder which cannot be disinfected.(h) If tools specified in this section are sterilized in accordance with the requirements outlined in Section 9. Note: Authority cited: Section 7.
Business and Professions Code. Reference: Section 7. Business and Professions Code.§ 9. Disinfecting Electrical Tools.(a) Clippers and other electrical tools shall be disinfected prior to each use in the following sequential manner: (1) First removing all visible debris; and(2) Disinfect with an EPA- registered disinfectant spray or wipe with demonstrated bactericidal, fungicidal, and virucidal activity used according to manufacturer's instructions.(b) All disinfected electrical tools shall be stored in a clean place.(c) All soiled electrical tools used on a client, or soiled in any manner, shall be placed in a container labeled Soiled, Dirty or Contaminated (excluding hot styling tools).
Note: Authority cited: Section 7. Business and Professions Code.
Reference: Section 7. Business and Professions Code. Procedures for Cleaning and Disinfecting Whirlpool Footspas and Air- Jet Basins.(a) As used in this section, whirlpool footspa or spa is defined as any basin using circulating water.(b) An air- jet basin is defined as any basin using an air jet stream system to move water.(c) After use upon each client, each whirlpool footspa or air- jet basin shall be cleaned and disinfected in the following sequential manner: (1) All water shall be drained from the basin.(2) The inside walls of the basin shall be scrubbed and cleaned of all visible debris with a clean brush, liquid soap (labeled as such on soap product) and water.
The spa basin shall be rinsed with water.(4) The spa basin shall be refilled with clean water.(5) The water in the basin shall be circulated with the correct amount (read manufacturer label for mixing instructions) of the EPA- registered hospital- liquid disinfectant that is labeled as a bactericide, fungicide and virucide, through the basin for at least 1. The spa basin must be drained, rinsed, and wiped dry with a new, clean paper towel.(7) Record this procedure in the pedicure equipment- cleaning log.
The log shall contain the date and time of each cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was done after a client.(d) At the end of each day and after the last client, each whirlpool footspa or air- jet basin shall be cleaned and disinfected in the following sequential manner: (1) The screen and any other removable parts shall be removed.(2) Scrub all visible debris from the screen, inside walls of the basin, any other removable parts, and the area behind them with a clean brush, liquid soap (labeled as such on soap product) and water.(3) Reinsert the clean screen and any other removable parts.(4) Fill the basin with warm water and detergent (labeled as such on detergent product) and circulate the detergent through the spa system for at least 1. Drain the detergent solution and rinse the basin.(6) Refill the basin with clean water and circulate the correct amount (read the label for mixing instructions) of the EPA- registered hospital- liquid disinfectant which the label claims is a bactericide, fungicide, and virucide through the basin for at least 1. Drain, rinse and wipe the basin dry with a new, clean paper towel and allow basin to dry completely.(8) Record this procedure in the pedicure equipment- cleaning log.
The log shall contain the date and time of each cleaning, initials of the person who completed the procedure, and shall indicate that the cleaning was done at the end of the day.(e) At least once each week, after completing the procedures provided in subsection (d) (1 through 6), each whirlpool footspa and air- jet basin shall not be drained and the following sequential procedures shall be followed: (1) Do not drain the disinfectant solution.